Introduce:

The HZCT type zero-sequence current transformer is used in conjunction with the relay protection device or signal when the power system generates zero-sequence grounding current to make the device components act and realize protection or monitoring.

When an electric shock or leakage fault occurs in the circuit, the secondary side of the transformer outputs the zero-sequence current, so that the equipment on the connected secondary line can be protected (cut off the power supply, alarm, etc.).

Mainfeatures:

  • Detection of unbalanced current: ZCT is designed to measure the unbalanced current in a three-phase electrical system, which is the sum of the three phase currents. This allows them to detect ground faults, which can occur when a fault current flows from one or more of the phase conductors to ground.
  • High sensitivity: ZCT is highly sensitive and can detect even small amounts of ground fault current. This helps to prevent damage to equipment and reduce the risk of electric shock to personnel.
  • Accuracy: ZCT is designed to provide accurate measurements of the zero-sequence component of the current, even in the presence of high levels of noise or interference.
  • Non-intrusive installation: ZCT is typically installed around the neutral conductor of a three-phase system, which means that they can be installed without the need to break the circuit or interrupt power to the load.
  • Frequency response: ZCT is designed to operate over a wide range of frequencies, typically from 50Hz to 400Hz, which makes them suitable for use in a variety of applications.
  • Low burden: ZCT is designed to have a low burden, which means that they do not significantly affect the operation of the circuit or the accuracy of other measurement devices in the system.

Application:

  • Electric fire monitorin
  • Fire prevention and leakage protection system
  • Electromagnetic relaying protection
  • Microcomputer protection, etc.
Electrical parameters Mechanical parameters
Frequency 50~400Hz Shell ABS(flame retardant grade 94-V0)
Rated input 10mA~5A Bobbin PBT
Measuring range 10%In~130%In iron core Ni steel/nanocrystalline
Rated output 0~1v (A or) 0~0.25mA Internal structure Environmentally friendly epoxy resin casting
Ratio difference ≤±0.1% Construction plan Screw fixing
Phase difference ≤±10 Working temperature -25℃~ +75℃
Dielectric Strength 2.5KV/1mA/1min Ambient Humidity ≤85%
Insulation resistance DC500V/1000MΩ/min Wiring method Terminal type/shielded twisted wire 1.5m
Model Specifications Dimensions
Reference current A B C D E F G
HZCT-1025 ≤100A 100 25 125 53 19 150 140
HZCT-1432 ≤225A 140 34 172 71 24 202 186
HZCT-1832 ≤400A 180 34 215 71 24 245 230
HZCT-2245 ≤630A 220 47 250 85 24 280 265
HZCT-2645 ≤800A 260 47 293 85 24 325 308
HZCT-3050 ≤1250A 300 500 customizable 85 24
HZCT-4050 ≤2000A 350 150 85 24
Electrical parameters Mechanical parameters
Frequency 50~400Hz Shell ABS(flame retardant grade 94-V0)
Rated input 10mA~5A Bobbin PBT
Measuring range 10%In~130%In iron core Ni steel/nanocrystalline
Rated output 0~1v (A or) 0~0.25mA Internal structure Environmentally friendly epoxy resin casting
Ratio difference ≤±0.1% Construction plan Screw fixing
Phase difference ≤±10 Working temperature -25℃~ +75℃
Dielectric Strength 2.5KV/1mA/1min Ambient Humidity ≤85%
Insulation resistance DC500V/1000MΩ/min Wiring method Terminal type/shielded twisted wire 1.5m

Dimensions

HZCT Type Zero-sequence Current Transformer-heyi
Model Specifications Dimensions
Reference current A B C D E F G
HZCT-1025 ≤100A 100 25 125 53 19 150 140
HZCT-1432 ≤225A 140 34 172 71 24 202 186
HZCT-1832 ≤400A 180 34 215 71 24 245 230
HZCT-2245 ≤630A 220 47 250 85 24 280 265
HZCT-2645 ≤800A 260 47 293 85 24 325 308
HZCT-3050 ≤1250A 300 500 customizable 85 24
HZCT-4050 ≤2000A 350 150 85 24