HYX Series HYX-85 Closed Type Current Transformer

Features

  • Double-screw fastening, safe, easy to install, portable
  • Two built in fixing methods: Base; Busbar mounting
  • Wide inner window, allowing clamping of big cables or bus-bars
  • Wide range of sizes to accommodate all the existing installations.
  • Primary current from 5Ato 6000A

HYX Series HYX-85 Closed Type Current Transformer covers a variety of specifications and models to meet the needs of different application scenarios, including power distribution networks, industrial facilities and commercial buildings.
Features
Double-screw fastening. safe, easy to install,portable Two built in fixing methods: Base; Busbar mounting Wide inner window, allowing clamping of big cables or bus-bars
Wide range of sizes to accommodate all the existing installations. Primary current from 5Ato 6000A

Applications
Current measurement, monitoring and protection for electrical wiring and equipment.
Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system air-condition equipment and automation-control system.
Current, power and energy monitoring device.
Relay protection device.

HYX Series HYX-85 Closed Type Current Transformer

FAQ

1.Question : Are you a factory or trading company ?
Answer: We are an SGS recognized OEM/ODM manufacturer factory with export license. We have an outstanding and experienced team made up of “A” player who have a passion for doing something great to create more value for customers world-wide.

2. Question :  Why choose cooperate with us ?
Answer :  — Right people, Right product, Right price ;
— Company-wide customer awareness ;
— Reliable Quality and All components from world leading suppliers ;
— Cost-effective export infrastructure and total supply chain management ;

3. Question : Where is your factory located ?  How can I visit there ?
Answer: With an ISO90001 certified factory located in  Yueqing city , zhejiang Province , P.R. China . It takes about 4 hours from SHANGHAI by train and 45 minute by air . It is very pleasure for clients to visit us.

4. Question :  Can you do OEM ?
Answer :  Yes, we have the ability to do OEM / ODM to meet clients’ requirements.

How to contact us ?

Send your Inquiry Details in the Below, Click “Send” Now! Free samples are waiting for you.

Model Input/Output(A) Burden(VA)
Class0.5 Class0.5S Class1
HYX-85 400/5 – – 10
HYX-85 500/5 – – 10
HYX-85 600/5 – – 10
HYX-85 800/5 10 – 10
HYX-85 1000/5 10 – 10
HYX-85 1200/5 10 – 10
HYX-85 1500/5 15 15 15
HYX-85 1600/5 15 15 15
HYX-85 2000/5 15 15 15
HYX-85 3000/5 15 15 15

FAQ

1. How do I select the correct current ratio for the HYX-85 current transformer?

Select the current ratio according to your circuit’s operating current and the connected meter’s secondary input rating. Avoid choosing an unnecessarily high primary rating, as this may affect measurement performance at low loads. Provide your operating current and meter specifications so we can confirm a suitable HYX-85 configuration.

2. How should I choose the accuracy class and rated burden?

The required accuracy class depends on your metering application. When selecting the rated burden, include both the connected instrument’s burden and the secondary cable burden. Please specify your required current ratio, accuracy class, cable length and cable cross-section so we can check the available configuration.

3. Will the HYX-85 fit my busbar or cable?

Fit must be checked against the HYX-85 dimensional drawing. For busbars, provide the width, thickness and number of bars passing through the window. For cables, provide the overall diameter, including insulation. Also check the available mounting space and terminal clearance before ordering.

4. Can the HYX-85 be connected to an energy meter or multifunction power meter?

Compatibility depends on the meter’s CT input specifications. The transformer’s secondary output must match the meter input, and the current ratio must be configured correctly in the meter. The frequency, accuracy requirements and total secondary burden should also be checked before installation.

5. Can the HYX-85 be installed without disconnecting the busbar or cable?

The HYX-85 is a closed-type current transformer, so the primary conductor must pass through its fixed window. Installation on an existing circuit generally requires isolation and temporary disconnection of the conductor. Follow the wiring diagram and polarity markings, and never leave a current-output CT secondary open while primary current is flowing.

Inquiry Now