News | company news | Jul 24,2024
Distribution cabinet introduction
A power distribution cabinet refers to an electrical product that plays the role of switching, controlling or protecting in the power generation, transmission, distribution, power conversion and consumption of the power system, with a voltage level of 3.6kV~550kV, mainly including high-voltage circuit breakers, high-voltage disconnectors and grounding switches, high-voltage load switches, high-voltage automatic reclosing and sectionalizers, high-voltage operating mechanisms, high-voltage explosion-proof distribution devices and high-voltage switch cabinets. The high-voltage switch manufacturing industry is an important part of the power transmission and transformation equipment manufacturing industry, and occupies a very important position in the entire power industry.
A power distribution cabinet refers to a low-voltage switch cabinet with all sides closed except the mounting surface. The electrical components such as switches, protection and monitoring control of this cabinet are all installed in a closed casing made of steel or insulating materials, which can be install against the wall or away from the wall. There can be no isolation measures between each circuit in the cabinet, or it can be isolate by a ground metal plate or insulating plate. Usually the door is mechanically interlock with the main switch operation. In addition, there is a protective table-type switch cabinet (i.e., control console), on which the control, measurement, signal and other electrical appliances are install. The protective switchgear is mainly use as a power distribution device at the process site.
The current transformer is a commonly use electrical equipment in the power distribution cabinet. In the combination process of the power distribution cabinet, it plays its role. Simply put, the current transformer converts a large current into a small current for measurement and protection. For example, 300/5 converts a large current of 300A into a small current of 5A. Generally speaking, 300A is call the primary current and 5A is call the secondary current. Why is it convert to 5A? This is the industry requirement based on the instrument measurement requirements.

Distribution cabinet introduction
--- END ---
Dec 22, 2025
Cómo seleccionar correctamente transformadores de corriente para exteriores en Sudamérica: ejemplos de RECT y OCT de HEYI Electric En la construcción y operación de sistemas eléctricos en Sudamérica, la elección del transformador de corriente para exteriores es fundamental. Trabajo en un proyecto eléctrico. Busco un transformador de corriente que aumente la seguridad de los equipos.… Continue reading Cómo seleccionar transformadores de corriente para exteriores en
Dec 18, 2025
HEYI Electric: Providing complete solutions for power engineering projects in Malaysia, from current monitoring to status indication. The biggest challenge, for companies in Malaysias power sector is keeping the system reliable and making monitoring easy. HEYI Electric offers more, than measurement products. HEYI gives a set that includes precision current transformers, flexible current transmitters and… Continue reading Position indicator switch is used to create solutions for Malaysia.
Dec 11, 2025
In Egypt you must pick the CTs with care. The need is strongest, in Cairo, Alexandria and Suez because the electric grid often changes, gets hot and carries loads. When the CTs are not stable or not accurate the safety system can fail. I have seen that the switchgear, the fuse breakers and the CTs… Continue reading How to Choose the Right Current transformer in Egypt