Which Current Transformer Is Better for Solar Projects: Ring CT or split-core CT?

News | company news | Sep 05,2026

1. Why are CT structures important in solar energy projects?

In solar projects, current transformers must not only meet the required conversion ratio, but also take into account the installation location, the size of the cables or busbars, and whether the electrical panel is new or already in service.

In solar power plants, current transformers are commonly used on the AC side to monitor the inverter output voltage, measure energy consumption, measure line parameters, and regulate output power. Toroidal and discharge current transformers are suitable for these applications but differ in their installation method.

By making the right design choices, the assembly of electrical panels can be simplified, the installation effort reduced, and subsequent monitoring of energy consumption facilitated.

RCT ring Type CT

2. When is a toroidal current transformer suitable for a solar module distribution system?

2.1 New distribution box for solar energy

Toroidal current transformers are particularly useful in solar power plants during the installation of the distribution board.

Cables or busbars can be routed through the current transformer to the connecting conductors. This makes toroidal current transformers suitable for the following applications:

  • Electric panel with solar inverter
  • New type of low-voltage distribution panel
  • electric meter panel
  • Diagram of the auxiliary power supply circuit
  • transformer power supply panel

HEYI’s RCT series current transformers offer different window sizes, allowing engineers to select the appropriate current transformer based on the actual conductor cross-section.

2.2 Why is it necessary to check the opening?

The suitability of a current transformer cannot be determined solely on the basis of the current transformation ratio.

When selecting an 800/5 A current transformer, engineers must check, for example, the cable diameter and busbar cross-section. A current transformer with the correct current rating but an insufficient internal diameter cannot be installed properly.

When planning the installation of new solar distribution panels, if the dimensions of the conductors are known, a toroidal current transformer represents a viable option.

Splict core CT DP HEYI

3. In which cases is the use of a dual-core computed tomography scanner most appropriate?

3.1 Modernization of the solar energy production system

Split current converters are particularly useful in projects where the solar power system is already operational .

HEYI DP current transformers are designed for wound installation without interfering with existing wiring. They also feature large internal openings to accommodate large-gauge cables or busbars, simplifying mounting and busbar installation.

This is useful when adding the following elements:

  • electricity meter
  • Supervision of the emergency services
  • Additional power dimension
  • Remote monitoring of the power supply
  • Modernized equipment for solar power plants

Instead of removing existing conductors, engineers can open the current transformer, install it on the cable or busbar, and then reconnect the secondary circuit.

3.2 Available buses and main escorts

In solar power plants, replacing or disconnecting large busbars can lead to additional work and downtime.

In this case, a detachable cable structure can simplify installation, especially if space in the existing distribution box is limited or if the cables are difficult to remove.

4. What type of current converter is best suited for high-current solar power lines?

4.1 Schematic representation of a large surface area solar inverter and transformer.

Large-scale solar power plants can combine the outputs of multiple inverters into a single high-voltage AC line. This means that engineers may need current transformers with the following transformation ratios:

1000/5A
1500/5A
2000/5A
3000/5A or more.

The HEYI DP-816 measuring instrument covers the current range from 1000/5A to 6000/5A and is therefore suitable for measuring high currents requiring large divided magnetic structures.

4.2 The relationship is not the only selection parameter.

In the case of power converters used in solar power plants , engineers must clarify the following points:

Primary current + Secondary current + Accuracy + Load + Busbar dimensions + Mounting type

For example, choosing a 3000/5 A current transformer does not automatically guarantee that it will be able to power a 3000 A busbar system.

The actual arrangement of the conductors must also be adapted to the current range of the transformer.

This is particularly important for large AC solar power distribution systems and low-voltage transformer circuits.

Current Transformer Exibition

5. Toroidal core current transformer or split core current transformer: which should an engineer choose?

There is no single optimal power converter design suitable for all solar energy projects.

For new solar distribution panels, toroidal current transformers provide a simple and convenient installation method, as conductors can be guided through the current transformers during panel assembly.

for existing solar power plants, because they can be installed on existing cables or busbars without the need to rebuild the electrical circuit.

For a solar power plant, engineers must confirm the transmission ratio, accuracy class, load, conductor cross-section, and plant type (new or modernized).

In the context of solar energy applications in North Africa, this approach can help engineers select power converters that meet both electrical requirements and practical installation conditions.

Suggested keywords

Main keywords:
Power converters for solar energy projects

Long-tail keywords:

  • Solar-powered toroidal transformer
  • split transformer for solar power
  • Power converters for solar power plants
  • Power converter for solar inverters
  • Computer-aided tomography of the solar distribution panel
  • Current transformers for energy monitoring
  • CT scan of a large bus
  • Power converter for solar energy monitoring

Compay:HEYI Electrical Co., Ltd.
Brand: HEYI/ASCT
Contact: Bethy
E-mail: heyi@heyiele.com             
Tel: 86-13968747975