SFCT Disconnected Switch Fues Current transformer

SFCT series current transformers are designed for integration into switch disconnectors and LV cabinets, providing reliable current measurement for monitoring and protection.

Introduce

The SFCT series current transformer is specifically engineered for integration inside switchable in-line fuse switch disconnectors and low-voltage distribution cabinets used by electrical distribution authorities. In these systems, the transformer provides accurate current measurement and protection signals required for feeder monitoring, load balancing, metering, and automation functions.
Its compact window-type design allows direct installation around busbars or insulated cables without requiring major structural modification to the switch disconnector housing. The SFCT ensures stable signal output even under varying load conditions and during switching operations, making it suitable for use in distribution feeder pillars, utility service cabinets, customer connection units, and compact LV switchboards.

Applications

  • Industrial power system: used for remote disconnection of main power supply in elevator shafts and machine rooms
  • High voltage system: achieving safe isolation in high-voltage digital control applications
  • Automotive electronics: battery disconnect switch for vehicle electrical systems
  • Process industry: application in equipment control in industries such as chemical, power, and petroleum

Sdandard

1‌. IEC standards: such as IEC 60044 series current transformer standards
2. UL certification: Complies with UL 5085 series standards
3. CE certification: Complies with the EU EMC Directive (EN 55022/EN 55015) and Low Voltage Directive (LVD)
4. IEC 60664-1 standard: Insulation coordination requirements for equipment in low-voltage systems

Technical Parameter

Turkish strip-type fuse disconnect switch current transformer HEYI

Turkish strip-type fuse disconnect switch current transformer HEYI2

Dimensions

Turkish strip-type fuse disconnect switch current transformer HEYI3

1. Can the SFCT current transformer be customized for different fuse switch disconnectors?

Yes. The SFCT current transformer can be customized according to the fuse switch disconnector structure, busbar dimensions, mounting space, current ratio, and electrical requirements. Customers can provide drawings, dimensions, or existing samples for evaluation.

2. What current ratios and accuracy classes are available for the SFCT current transformer?

The SFCT can be manufactured with different primary and secondary current ratios according to project requirements. Various metering and protection accuracy classes are also available. Please provide the required current ratio, accuracy class, and burden so that we can recommend the correct specification.

3. What busbar sizes can the SFCT current transformer accommodate?

The suitable busbar size depends on the internal window dimensions and the available installation space inside the fuse switch disconnector. Please provide the busbar width, thickness, and surrounding mounting dimensions, and we can confirm the appropriate SFCT model or customize the structure.

4. Can the SFCT current transformer be used for both metering and protection?

Yes. Depending on the winding design, accuracy class, current ratio, and burden, the SFCT current transformer can be designed for current measurement, energy metering, monitoring, or protection applications in LV distribution systems.

5. What information is required to select the correct SFCT current transformer?

To select the correct SFCT current transformer, please provide the primary/secondary current ratio, accuracy class, rated burden, busbar dimensions, system voltage, frequency, and available installation space. A drawing or photo of the fuse switch disconnector is also helpful for confirming mechanical compatibility.

Inquiry Now

    JOIN US

    Register as one of our members and provide you with the latest product and discount information.