HYB -A is a single-phase /three-phase automotive current transducer that isolates and converts AC current parameters of the power grid into linear DC analog signals .
It supports output in the form of 0-20 mA/4-20 mA/0-5 V/0-10 V, with an accuracy of 0.2 and 0.5 Class . It supports inputs of 0.1A, 1A, 5A, etc. (can match current transformers ).
It has the characteristics of quadruple isolation of input/output/power supply/housing , AC/DC Features include 80–270V wide power supply, ≤400 ms response time, and DIN35 rail mounting.

2x long-term, 10x/10s, dielectric strength: AC 2 kV/1 min, insulation resistance >100 MΩ @ DC 500 V; operating environment: 0–50°C / <80% RH. One-year warranty.
These parameters mean that HYB-A is suitable for both standard loop signals in process control and electrical parameter acquisition in buildings and distribution cabinets, achieving a very stable engineering balance between cost, versatility, and reliability.
Output and load
Current type (4–20 mA/0–20 mA):
The current loop compliance voltage is approximately 10 V, and the maximum load is ≈10 V/20 mA=500 Ω.
Voltage type (0–5 V/0–10 V):
To ensure linearity and ripple, the load resistance should be ≥ Vout/10 mA (e.g., 0–10 V ≥ 1 kΩ).
Matching current transformer and range:
the input side is connected to the secondary side (5 A/1 A), and is selected according to the primary rated current and current ratio ;
if there is surge/inrush current, the 2× long-term/10× short-term overload window can be used to ensure that the equipment is not saturated and does not falsely alarm.
Zero/full scale calibration: Panel ZERO/SPAN fine-tuning can be used for system-level calibration.
Installation and power supply:
DIN rail +80–270 V AC/DC compatible, suitable for 220–240 V/50 Hz and power grid fluctuations common in Southeast Asia; 12/24/48VDC can also be customized to match PLC cabinets.

| plan | advantage | Limitations | HYB-A Location |
| Shunt resistor + isolation amplifier | Low cost, high bandwidth | Heat generation, voltage drop, and careful isolation design are required | HYB-A eliminates the complexity of discrete isolation and is more robust overall |
| Open-loop Hall sensor | No need for series CT, considerable bandwidth | Zero drift, temperature drift, magnetic noise | HYB-A is more user-friendly in terms of accuracy and long-term stability |
| Smart meter built-in transmitter | Integration | Channel/range limited | HYB-A1 is more flexible, easy to customize by OEM, and easy to expand multiple channels. |
Conclusion:
In terms of 0.2-level accuracy, universal interface and system adaptability, automotive current transducer HYB-A is a universal electronic component for distribution cabinets, industrial control and building BAS .
Key application scenarios and implementation suggestions
Industrial Automation/Process Control
Pump/fan/compressor current monitoring → 4–20 mA is connected to the DCS/PLC and AI module to achieve overload/no-load diagnosis and energy consumption management.
Monitoring OEE of production line equipment → Using current curves as “virtual sensors” to identify standby and load conditions.
Note : Current loop power supply, load ≤ 500 Ω; avoid strong interference circuits when wiring in the cabinet; use delay filtering for startup peak current to avoid false alarms.
Building and Data Center Power Distribution
Distribution circuit branch current collection (0–10 V or 4–20 mA → BAS/SCADA) for sub-metering and PUE monitoring.
UPS/generator parallel monitoring:
Utilize 10×/10s short-term overload margin to cope with switching shock.
Water/Municipal Affairs and New Energy Support
Pumping station/wastewater treatment plant: Pump efficiency decay/clogging is measured by current;
Rooftop PV AC side: Inverter output branch current collection (pay attention to temperature, humidity and anti-condensation).
Charging Infrastructure and Small Electromechanical Equipment
AC charging pile: Use current transmission and relay/temperature to achieve overcurrent/temperature rise linkage protection;
OEM complete distribution box: with 0.2% accuracy and wide power supply, it reduces part numbers and accelerates integration.
Access and Compliance
Low-voltage power distribution/measurement products generally require reference to relevant IEC/EN standards and local registration/inspection according to national regulations (e.g., Malaysia’s SIRIM, Thailand’s TISI, Indonesia’s SNI, etc.).
Whether this is mandatory depends on the intended use and electrical category. Consult with local authorities.
Environmental adaptability:
Tropical environments with high humidity, salt spray, and mildew risk are high, so moisture-proof/mildew-proof coating and terminal anti-loosening design are recommended.
For outdoor enclosures, anti-condensation heating strips and IP protection solutions are recommended.
Applications with dynamic fast loads (<100 ms level) need to evaluate a response upper limit of ≤400 ms.
If high-speed capture is required, event detection should be superimposed on the upper-level system or a dedicated high-speed sensor should be used.
Environmental limits:
Standard version 0–50°C, <80%RH; for extreme high temperature, high humidity/condensation environments, please use heating, dehumidification and thermal design or choose the enhanced OEM version.
Conclusion
With high precision, universal output, wide power supply range, and comprehensive isolation, the HYB-A1 offers plug-and-play advantages in industrial automation, building BAS, data center power distribution, water utilities, and renewable energy applications.
Compay:HEYI Electrical Co., Ltd.
Brand: HEYI/ASCT
Contact: Bethy
E-mail: heyi@heyiele.com
Tel: 86-13968747975
--- END ---
Dec 18, 2025
HEYI Electric: Providing complete solutions for power engineering projects in Malaysia, from current monitoring to status indication. The biggest challenge, for companies in Malaysias power sector is keeping the system reliable and making monitoring easy. HEYI Electric offers more, than measurement products. HEYI gives a set that includes precision current transformers, flexible current transmitters and… Continue reading Position indicator switch is used to create solutions for Malaysia.
Dec 11, 2025
In Egypt you must pick the CTs with care. The need is strongest, in Cairo, Alexandria and Suez because the electric grid often changes, gets hot and carries loads. When the CTs are not stable or not accurate the safety system can fail. I have seen that the switchgear, the fuse breakers and the CTs… Continue reading How to Choose the Right Current transformer in Egypt
Dec 10, 2025
Application Analysis of ICT Isolation current transformer in Photovoltaic Systems The article deals in depth with an analysis of the ICT series isolation current transformer plug-in current transformers from the company HEYI Electric, their role within the photovoltaic system, the usage methods, advantages, and practical applications. HEYI Electric’s ICT Isolation current transformer In other words,… Continue reading How Isolation Current Transformer Optimize Accuracy in PV system