Din Rail Single-Phase Electronic Energy Meter

The HXN-DDS100 (1P) single-phase electronic energy meter adopts

single-chip control. It has the characteristics of few peripheral

components, simple structure, high reliability, low power consumption,

and long lifespan. It can be used to measure single-phase AC active

energy with a rated frequency of 50Hz. The performance parameters

of this product meet all the technical requirements for single-phase

electronic energy meters in the GB/T17215.321-2008 “Class 1 and

Class 2 Static AC Active Energy Meters” standard.

The HXN-DDS100 (1P) single-phase electronic energy meter adopts

single-chip control. It has the characteristics of few peripheral

components, simple structure, high reliability, low power consumption,

and long lifespan. It can be used to measure single-phase AC active

energy with a rated frequency of 50Hz. The performance parameters

of this product meet all the technical requirements for single-phase

electronic energy meters in the GB/T17215.321-2008 “Class 1 and

Class 2 Static AC Active Energy Meters” standard.

 

Features:

  • Measurement of active energy without the need for calibration.
  • Uses the specialized measuring chip ADE7755.
  • Uses the latest specialized integrated circuit with a digital remainder algorithm, greatly improving the dynamic working range of themeter and achieving an actual overload capacity of more than 10times.
  • Good error linearity within the range of 5%Ib~Imax.
  • Few peripheral components, low power consumption, and simple meter structure.
  • All components inside the meter are selected for long lifespan and high reliability.
  • Display mode: LCD.

Equipped with remote power disconnection function.

Output interface: RS485.

 

Application:

Electrical Troubleshooting: Use it to diagnose electrical problems, verify voltage levels, and analyze power consumption.

DIY Projects: Ideal for hobbyists and DIY enthusiasts working on electronics, home wiring, and small-scale electrical projects.

Commercial and Industrial Maintenance: Essential for maintenance professionals working in commercial buildings and industrial facilities.

Energy Auditing: Helps in energy audits by measuring power consumption and identifying areas for improvement.

Automotive Electrical Work: Valuable for automotive technicians working on vehicle electrical systems.

Educational Use: Suitable for educational purposes in electrical engineering and electronics courses.

Technical Parameters

Measurement Accuracy Voltage:0.5 Class  Current:0.5 Class  Active Power(Watt):1.0 Class
Reactive Power(var):1.0 Class    Power Factor:1.0 Class      Frequency:±0.2Hz      Active Energy(kwh):1.0 Class
Singal input Wiring Mode:3 Phase 4 Wires/3 Phase 3 Wires      Related Current:AC1A/AC5A
Related Voltage:AC57.7V,AC100V,AC220V,AC380V
Voltage:1.2 times(continuous),2 times/1 second(instantaneous)
Current:1.2 times(continuous),10 times/5 seconds(instantaneous)
Power Consumption: Voltage:<1VA/Phase Current:<0.4VA/Phase
Impedance voltage: >300KΩ current: <20mΩ
Impedance:Voltage:>400kΩ Current:<20mΩ
Frequency:45-65Hz
Auxiliary power supply Working Range:AC85V~265V/DC100V-300V or AC220V
Power Consumption:<4VA
OptionalExtended Function Communication Port:1 Loop Rs485 ,Modbus-RTU Protocol
Baud Rate:1200~38400bps,the factory default is 9600bps
Switching Input:Passive dry contact
The switch output support 3 relay output, capacity: AC 250V/5A, DC 30V/5A
Switching Output Capacity:AC250V/5A,DC30V/5A
Environment Working temperature: -10°C ~+55°C
Storage temperature: -25°C ~+70°C
Relative humidity is less than 93%, no corrosive gas
Elevation≤2500m
safety Insulation resistance >100MΩ
AC withstand voltage AC 2KV
Electromagnetic compatibility ESD level 4
Electrical fast transient burst level 4

Din Rail Single-Phase Electronic Energy Meter-heyi

Technical Parameters

Measurement Accuracy Voltage:0.5 Class  Current:0.5 Class  Active Power(Watt):1.0 Class
Reactive Power(var):1.0 Class    Power Factor:1.0 Class      Frequency:±0.2Hz      Active Energy(kwh):1.0 Class
Singal input Wiring Mode:3 Phase 4 Wires/3 Phase 3 Wires      Related Current:AC1A/AC5A
Related Voltage:AC57.7V,AC100V,AC220V,AC380V
Voltage:1.2 times(continuous),2 times/1 second(instantaneous)
Current:1.2 times(continuous),10 times/5 seconds(instantaneous)
Power Consumption: Voltage:<1VA/Phase Current:<0.4VA/Phase
Impedance voltage: >300KΩ current: <20mΩ
Impedance:Voltage:>400kΩ Current:<20mΩ
Frequency:45-65Hz
Auxiliary power supply Working Range:AC85V~265V/DC100V-300V or AC220V
Power Consumption:<4VA
OptionalExtended Function Communication Port:1 Loop Rs485 ,Modbus-RTU Protocol
Baud Rate:1200~38400bps,the factory default is 9600bps
Switching Input:Passive dry contact
The switch output support 3 relay output, capacity: AC 250V/5A, DC 30V/5A
Switching Output Capacity:AC250V/5A,DC30V/5A
Environment Working temperature: -10°C ~+55°C
Storage temperature: -25°C ~+70°C
Relative humidity is less than 93%, no corrosive gas
Elevation≤2500m
safety Insulation resistance >100MΩ
AC withstand voltage AC 2KV
Electromagnetic compatibility ESD level 4
Electrical fast transient burst level 4

    Inquiry Now