NSQ Window Type Current Transformer

  • Frequency:50/60Hz
  • Rated Input:1A-5000A
  • Measuring range:5%In-120%In
  • Rated Output:1A,5A
  • Ratio Voltage:0.72KV (AC)
  • Dielectric strength:3.0KV/1mA/1min
  • Insulation Resistance:DC500V/100MΩ min
  • Case:PC/UL94-V0
  • Bobbin:PBT
  • Core:Silicon steel

Window Type Current Transformer

Introduce:

NSQ Series window type current transformer is designed for electric power systems of 50/60Hz rated frequency and rated voltage 0.66kV. They are used for indoor mounting.

Features:

  • The window type current transformer is Made According To IEC-185 Standard.
  • Class Of Accuracy: 1.0 (see table)
  • Rated Voltage: 600V (see table)
  • Rated Sec. Current 5A(or 1A on reque.
  • Security Factor: FS5
  • Working Temperature Range: ABS plastic case, toally enclosed, built-in cover, and several ampere outputs at secondary side iron plate for fixing metal housing-2 pieces-1, iron bar and acrew for fixing copper bar-3 pieces.

Applications:

  • Current measurement, monitoring and piotection for electrical wiring and equipment.
  • Current and power measurement for electric motors,lighting,air compressor,heating and ventilation system,air-condition equipment and automation-control system.
  • Current,power and energy monitoring device.
  • Relay protection device.
Electrical Parameter Mechanical Parameter
Frequency 50/60Hz Case PC/UL94-V0
Rated Input 1A-5000A Bobbin PBT
Measuring range 5%In-120%In Core Silicon steel
Rated Output 1A,5A Construction Screw
Ratio Voltage 0.72KV (AC) Operating Temp -25℃~+75℃
Dielectric strength 3.0KV/1mA/1min Operating Humidity ≤85%
Insulation Resistance DC500V/100MΩ min Output Connection Terminal
Model Primary /secondary Busbar Hole Dimension Rated Burden (VA) Class Rated Voltage Rated Frequency
NSQ-30 30/5A-300/5A 30*10mm 1.5-5 0.5/1.0 0.72KV 50/60Hz
NSQ-40 50/5A-400/5A 40*10mm 1.5~10 0.5/1.0 0.72KV 50/60Hz
NSQ-55 100/5A~600/5A 55*10mm 1.5~10 0.5/1.0 0.72KV 50/60Hz
NSQ-85 600/5A-1600/5A 60*10mm 1.5~10 0.5/1.0 0.72KV 50/60Hz
NSQ-125 800/5A-3000/5A 100*10mm 15 0.5/1.0 0.72KV 50/60Hz

Diagram

Dimensions

Dimensions(mm)
A B C D E F
79 87 42 30 22 66
79 87 42 41 30 66
103 113 42 60 47 66
151 166 45 101 71 70
192 212 45 126 126 70

Install Method

Accuracy Test

FAQ

1. How do I select the right NSQ window-type current transformer?

Select an NSQ current transformer according to your primary current, required secondary output, accuracy class, rated burden, and conductor dimensions. Check both the window opening and overall dimensions to ensure compatibility with your switchgear or distribution panel. Provide these specifications when requesting a model recommendation.

2. Can NSQ current transformers accommodate both busbars and cables?

NSQ window-type current transformers allow the primary conductor to pass through the opening. Suitability depends on the busbar width and thickness or the cable’s outside diameter, including insulation. For multiple busbars, provide their combined dimensions and arrangement so the required clearance can be checked against the model’s dimensional drawing.

3. Should I choose a 1A or 5A secondary output?

Choose a secondary output that matches the rated CT input of your connected meter or monitoring device. NSQ current transformers are listed with 5A output, with 1A available on request. For longer secondary wiring, a 1A circuit can reduce cable burden compared with a 5A circuit using the same conductor size. Confirm the complete circuit burden before ordering.

4. What accuracy classes and rated burdens are available for NSQ current transformers?

The NSQ model table lists Class 0.5 and Class 1.0 options. Available rated burdens depend on the model and current ratio, so the required accuracy and VA rating must be confirmed together. Include the burden of the connected instrument and secondary wiring when selecting the CT to ensure the circuit meets the specified operating conditions.

5. What information is needed for an NSQ current transformer quotation?

Please provide the primary-to-secondary current ratio, accuracy class, rated burden in VA, operating frequency, busbar or cable dimensions, and order quantity. Also specify any installation space limits and required technical documents. If you are replacing an existing CT, a clear nameplate photograph and dimensional drawing will help identify a suitable replacement.