Product Category

Search

Single phase AC Voltage Transducer HYB-V

  • AC voltage Input: 100V,300V ,450V,600V etc.
  • Accuracy: 0.2%、0.5%
  • Response time: ≤400ms
  • Output Voltage: 0~ 10VDC, 0~ 5VDC (load resistance = input voltage /10mAdc)
  • Output Current: 0~20mAdc ,4~20mAdc(Load Resistance = 10Vdc / output current)

Single phase voltage transducer The HYB-V series.

Single phase voltage transducer are essential components in electrical systems for monitoring and controlling electrical voltages in single-phase circuits. They play a crucial role in converting voltage levels into standardized output signals, facilitating real-time monitoring and data acquisition.

Feature :

  • Voltage Measurement: Single-phase voltage transducer are designed to measure and monitor voltage levels in single-phase electrical circuits, ensuring accurate and reliable voltage monitoring.
  • Precision Voltage Measurement: These transducer offer high accuracy to provide precise voltage measurements, which are critical for ensuring the proper functioning of electrical equipment and systems.
  • Output Signals: Single-phase voltage transducers convert the measured voltage levels into standardized output signals, typically in the form of voltage outputs (e.g., 0-10V or 0-5V) or current outputs (e.g., 4-20mA current loop signals). These output signals enable monitoring, control, and data acquisition.
  • Isolation and Safety: To ensure operational safety, these transducers are equipped with robust insulation to isolate the voltage measurement circuit from external electrical contact.
  • Immunity to Interference: They are built to resist electromagnetic interference and noise, ensuring stable and accurate voltage measurement results.
  • Communication Interfaces: Some single-phase voltage transducer feature communication interfaces, allowing for data transmission to monitoring systems or data acquisition devices for remote monitoring and control.

Application:

  • Voltage Monitoring: Single-phase voltage transducers are extensively used for monitoring voltage levels in single-phase electrical systems. This is essential for ensuring that voltage remains within acceptable limits to prevent equipment damage or malfunction.
  • Load Control: They are employed for load control in various applications. By monitoring voltage levels, these transducers can adjust or control connected loads to maintain system stability and safety.
  • Power Quality Analysis: Single-phase voltage transducers are used for power quality analysis, helping to identify and rectify voltage disturbances, such as sags, surges, and voltage spikes.
  • Renewable Energy Systems: They play a vital role in renewable energy systems like solar and wind power installations, where monitoring the voltage of power sources is crucial for efficient energy generation.
  • Uninterruptible Power Supplies (UPS): In UPS systems, single-phase voltage transducers monitor incoming power voltage to trigger the switch to battery power when voltage anomalies occur, ensuring continuous power supply.
  • Data Centers and Critical Facilities: These transducers are used to monitor voltage stability in data centers and critical facilities to safeguard sensitive electronic equipment and prevent data loss.

In conclusion, single-phase voltage transducers are crucial components in electrical systems for monitoring and controlling single-phase voltage. Their applications range from voltage monitoring and load control to power quality analysis and ensuring uninterrupted power supply in critical facilities. These transducers are essential for maintaining the stability, safety, and efficiency of electrical systems across various settings.

AC voltage Input 100V,300V ,450V,600V etc.
Allow overload Voltage×1.2 times the nominal value lasts;
Voltage×2 times the nominal value 5s
Accuracy 0.2%、0.5%
Response time ≤400ms
Output Voltage 0~ 10VDC, 0~ 5VDC (load resistance = input voltage /10mAdc)
Output Current 0~20mAdc ,4~20mAdc(Load Resistance = 10Vdc / output current)
Output ripple ≤0.5% RO peak
Work environment temperature and humidity 0~50℃/<80% relative humidity(no condensing)
Storage conditions temperature and humidity -20~70℃/ less than 70% relative humidity (no condensation)
Aux.Power supply AC/DC 80V~270V can be customized special specifications (DC12V, 24V, 48V)
Isolate Input/output/power/shell
Power consumption DC about 3W, AC about 4VA
Shell material ABS fireproof material
weighs about 300 grams
Compressive strength AC2Kvrms /min
Insulation resistance more than 100 m Ω DC500V
Shape and size 120 (L) × 55 (W) × 75 (H) mm
Installation 35mm standard guide rail or fixed on the cabinet

Diagram

Single phase AC Voltage Transducer HYB-V-heyi

Inquiry Now

    JOIN US

    Register as one of our members and provide you with the latest product and discount information.