Product Category

Search

Special type transformer

Introduce:

Rectifier & Furnace Transformers that are used in special industrial applications such as smelting and processing operations.

Features:

  • Ideal for emergency situations and rapid response
    Rugged but light design to facilitate transport
    Compact low profile design for ease of transport
    Two-core design with its flexibility to control OLTC step voltage and current
    Use of traditional transformer technology
    Balances the load
    Improves the utilisation of existing assets
    Increased fire safety
    Reduced clearance and transformer installation footprint
    Reduced civil engineering costs
    Extended transformer life
    Increased transformer overloading limits above nameplate
    Increased environmental protection
Carbide furnace transformer JB/T6303-92
model
Capacity
(kVA)
once
voltage
(kV)
secon
dary
voltage
(kV)
Vector
group
type
of
cooling
National standard Enterprise standard
No-load
loss
(kW)
On
load
loss(kW)
No-load
current
(%)
Short
circuit
imped
ance%
On load
loss(kW)
No-load
current
(%)
HCS-1000 6 57-73 D.do-12 Oil 3.27 21.4 3 6~8 17 1.5
HCS-1250 6.3 immersed 4.08 26.7 3 6~8 21.3 1.5
HCS-1600 10 67-83 self 4.4 28.8 3 6~8 23 1.5
HCS-1800 10.5 cooling 4.95 32.4 3 6~8 24.3 1.5
HCS-2000 72-96 5.5 36 3 6~8 27 1.3
HCS-2500 6.85 40.6 3 6~8 30.5 1.3
HCS-3150 35 90-110 D.do-12 Cooling 7.8 51.2 3 6~8 35.9 1.2
HCS-3600 Y.dp-11 way 8.9 58.5 3 6~8 41 1.2
HCS-4000 9.1 65 3 6~8 46 1.2
product model Rated
capacity
(kVA)
Rated voltage(V) Join group label Loss(kW) No-load
current
(%)
Short
circuit
impe
dance%
High
pressure
Medium
voltage
The low
pressure
no-load load
ZHSZK-630/10 630 10000 6000 11x√3 Y/Y⊥入 1.4 8.3 6
ZHSZK-1000/6.3 1000 6300 246 Y/Y⊥入
ZHSZK-1200/6.3 1200 6300±5% 45 Y/Y-入 2
ZHSZK-1600/10 1600 6300±5% 345 D.YnlID.do 7.5
ZHSZK-1800/35 1800 35000 5.55~83.527级 Y.△/Y-入Y-入 8.2 29.8 7.1
ZHSZK-2000/10 2000 10000±10% 77~13427级 Y/YLY,△/Y⊥λ 3.54 18.32 8
ZHSZK-2000/35 2000 35000 125~25027级 Y/Y⊥入
ZHSZK-4000/35 4000 35000 6000 100~17527级 △/(Y)/Y⊥λ,Y⊥入 6.93 42.87 8
ZHSZK-4400/10 4400 10000 268~311 Y/Y⊥入,Y⊥入
ZHSZK-5100/10 5100 10000 565 Y/Y⊥入
ZHSZK-5900/35 5900 35000 D.YnD.Y5 7.72 64.62 7
ZHSZK-6200/35 6200 35000 △/Y⊥λ 8.2 69.3 9.38
Yellow phosphorus furnace transformer JB/T85606-1996
model
Capacity
(kVA)
Rated voltage(V) National standard
High
pressure
(kV)
The low
pressure(kV)
No-load
loss
(kW)
On load
loss
(kW)
No-load
current
(%)
Short
circuit
impe
dance%
HLS-2000 6
6.3
10
35
180,167.5,155,142.5,130 4.8 29 3 7~8
HLS-2500 215,200,185,168,130 5.7 34 3 7~8
HLSSP-2150 230,215,200,180,130 6.8 41 3 7~8
HLSSP-4000 245,231,218,203,196,178,140 8.2/9.4 51/58 2.8 7~8
HLSSP-500 260,245,232,220,199,182,140 9.8/11.5 59/68 2.6 6~8
Yellow phosphorus furnace transformer JB/T85606-1996
model
Capacity
(kVA)
Rated voltage (V) National standard
once
voltage
(kV)
secon
dary
voltage
(kV)
Vector
group
type
of
cooling
pressure
regulating
No-load
loss
(kW)
On load
loss
(kW)
No-load
current
(%)
Short
circuit
impe
dance%
HKS-1000 6
6.3
10
10.5
35
73 69 D.do-12 Oil
immersed
self
cooling
Manual
high
voltage
without
excitation
3.27 21.4 3
HKS-1250 65 61 4.08 26.7 3
HKS-1600 57 4.4 28.8 3
HKS-2000 80 70 5.5 36 3
HKS-2500 75 71 67 6.85 40.6 3 6~8
HKSSP-3150 98 94 7.8 51.2 3
HKSSP-4000 90 86 92 9.1 65 3
HKSSP-5000 113~90 10.2 71.4 3
HKSSP-6300 126~100 11.8 90 2.5
model
Capacity
(kVA)
once
voltage
(kV)
secon dary
voltage
(kV)
Strong
oil water
Vector
group
Regu
lating
way
No-load
loss
(kW)
On
load
loss
(kW)
No-load
current
(%)
Short
circuit
impedance
small/large%
Reactor
capacity
(kvar)
HS-630 6
6.3
10
10.5
11
200 170 Manual
high
voltage
without
excitation
Oil
immersed
self
cooling
cooling
way
2.2 11 3
HS-800 160 98 2.7 13.5 2.9 10.5/25
HS-1000 3.1 16 2.8
HS-1250 210 180 3.7 18.5 2.6
HS-1600 121 104 D-Y 4.6 24 2.5 9.5/23
HS-2000 do-11 5.6 28 2.4
HS-2500 220 190 6.7 34.5 2.3
HSSP-3150 127 110 8.0 41.5 2.2 8.5/20
HSSP-4000 8.25 51.5 2.1
Electroslag furnace transformer JB/T8447-1996
model
Capacity
(kV)
once
voltage
(kV)
secon
dary
voltage
(kV)
pressure
regulating
Regulating
level
External
saturation
reactor
capacity
(KVAR)
Short
circuit
impedance
%
HZ-200 6

6.3

10

35

30~60 rectifier 5~7
HZ-600 35~70
HZ-800 40~80
HZ-1250 45~90 On-load 19~27 1330 when 35KV 6-8
HZ-1600 45~90 voltage 1720 When 10KV 5-7
HZ-2000 50~100 regulating 2130
HZ-2500 55~110 (Load is used 2690
HZ-3150 60~120 Tap switch) 3290

Diagram

Special type transformer-heyi

Principle Diagram

Special type transformer-heyi

    Inquiry Now

      JOIN US

      Register as one of our members and provide you with the latest product and discount information.