RCD/RCMU HYCA-05 Type B Residual Current Sensor

  • Portable EV charger(Mode 2 IC-CPD)
  • AC Charging pile、Wallbox(Mode 3 EV charger)
  • Mode 4 EV charger
  • Ground fault detection
  • DC system leakage current detection
  • Photovoltaic inverter residual current detection

HYCA type AC DC leakage current sensor

Introduce:

HEYI Electrical company ASCT brand new product  HYCA type AC DC leakage current sensor is a Leakage Protection Residual Current sensor specifically developedfor EV-charging providing all-current sensitivity. Charging of electric vehicles ata standard wall socket or a wall box requires protection devices against DC faultcurrents to avoid electric shock. Installed type A residual current circuit-breakers(RCCBs) are unable to identify and deactivate DC fault currents.

Features:

  • Small volume and footprint for integration into compact IC-CPD.
  • Avoids hazardous situations with DC fault currents.
  • Protects RCCB type A from saturation.
  • Saves costly type B RCCD.
    Volume optimized.
  • AC/DC-current sensitivity at low cost.
  • Protects RCCB type A from saturation.
  • Self-monitoring and test functions.
  • Robust mechanical design suitable for IC-CP.

Technology:

  • ault current detection according to IEC 62752 or UL 2231.
  • Frequency range DC up to 2 KHz.
  • Load current up to 80 Arms (1-phase) or 3 x 32 Arms (3-phase).
  • Switching output for 6 mA DC and 30 mA AC (acc. to IEC 62752)
  • Integrated self-monitoring and test functions.
  • Measurement resolution of 0.2 mA.
  • Variants with pass through opening or with integrated primary conductors.
  • Differential current range 0~300 mA.
  • Robust mechanical design suitable for IC-CPD environmental requirements (e.q. drop test)
  • Widely usable in harsh electronic environment (e.g, resistant to external maanetic fields)
  • The sensor can trigger an automatic shut-off in case ofhazardous electrical faults (DC and AC) according to lEC 62752 or UL2231.

Standard:

model Corresponding standards DC trigger threshold AC trigger threshold
HYCA-05 IEC62955 6mA /

Electrical/Reliability Characteristics

RCD/RCMU HYCA-05 Type B Residual Current Sensor-heyi

Trip-Current (residual current related characteristics)

RCD/RCMU HYCA-05 Type B Residual Current Sensor-heyi

Trip-Time (residual current related characteristics)

RCD/RCMU HYCA-05 Type B Residual Current Sensor-heyi

NoTrip-Time (residual current related characteristics)

RCD/RCMU HYCA-05 Type B Residual Current Sensor-heyi

Diagram

RCD/RCMU HYCA-05 Type B Residual Current Sensor-heyi

Principle Diagram

RCD/RCMU HYCA-05 Type B Residual Current Sensor-heyi

Inquiry Now

    JOIN US

    Register as one of our members and provide you with the latest product and discount information.