HY-ZCT-18031 Type Zero-sequence Current Transformer

Introduce:

The HY-ZCT-18031 type zero-sequence current transformer is used in conjunction with the relay protection device or signal when the power system generates zero-sequence grounding current to make the device components act and realize protection or monitoring.

When an electric shock or leakage fault occurs in the circuit, the secondary side of the transformer outputs the zero-sequence current, so that the equipment on the connected secondary line can be protected (cut off the power supply, alarm, etc.).

Mainfeatures:

  • Detection of unbalanced current: ZCT is designed to measure the unbalanced current in a three-phase electrical system, which is the sum of the three phase currents. This allows them to detect ground faults, which can occur when a fault current flows from one or more of the phase conductors to ground.
  • High sensitivity: ZCT is highly sensitive and can detect even small amounts of ground fault current. This helps to prevent damage to equipment and reduce the risk of electric shock to personnel.
  • Accuracy: ZCT is designed to provide accurate measurements of the zero-sequence component of the current, even in the presence of high levels of noise or interference.
  • Non-intrusive installation: ZCT is typically installed around the neutral conductor of a three-phase system, which means that they can be installed without the need to break the circuit or interrupt power to the load.
  • Frequency response: ZCT is designed to operate over a wide range of frequencies, typically from 50Hz to 400Hz, which makes them suitable for use in a variety of applications.
  • Low burden: ZCT is designed to have a low burden, which means that they do not significantly affect the operation of the circuit or the accuracy of other measurement devices in the system.

Application:

  • Electric fire monitorin
  • Fire prevention and leakage protection system
  • Electromagnetic relaying protection
  • Microcomputer protection, etc.

How does zero sequence current transformer work

A zero sequence current transformer (ZCT) is a specialized type of current transformer that is used to measure the unbalanced or zero sequence currents in a three-phase power system. These currents are typically caused by faults or disturbances in the system, and they can be difficult to detect and measure accurately.

The ZCT works by using a specially designed core that allows it to measure the vector sum of the three phase currents. This is achieved by winding the primary conductor through the core in a specific configuration, which causes the magnetic field produced by each phase current to cancel out the others.

When a fault or disturbance occurs in the system, it can cause an unbalanced or zero sequence current to flow. This current will not be cancelled out by the magnetic field in the ZCT core, and will instead produce a voltage signal in the secondary winding of the transformer. This voltage signal can then be used to accurately measure the unbalanced or zero sequence current.

The output of the ZCT can be used for a variety of applications, such as protective relaying, fault detection, and power quality monitoring. By accurately measuring these types of currents, the ZCT can help improve the safety and reliability of the power system.

Model Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-18031 0.5A/0.5mA 0.5A 100mA 0.5mA 400A 180*31mm 0.5
1A/1mA 1A 100mA 1mA 400A 180*31mm 0.5
1A/0.5mA 1A 100mA 0.5mA 400A 180*31mm 0.5
Model Specifications Rated Pr.Current(A) Min. Current(mA) Rated Sec. Current (mA) Max current of system window size(mm) Accuracy Class
HY-ZCT-18031 0.5A/0.5mA 0.5A 100mA 0.5mA 400A 180*31mm 0.5
1A/1mA 1A 100mA 1mA 400A 180*31mm 0.5
1A/0.5mA 1A 100mA 0.5mA 400A 180*31mm 0.5

Dimensions

HY-ZCT-18031 Type Zero-sequence Current Transformer-heyi

    contact us

    24Hs online service   365Ds NON-Stop Production   20Ys Professional Manufacturers Professional designer and manufacturer of current transformer,cooperated with Siemens ,schneider Fuji electrical softbank LG samdsung.
    Company HEYI Electrical CO.,LTD Contact person Bethy
    Tel 86-13968747975 E-mail bethy@heyiele.com
    ADD Xinguang Ind.Zone, Liushi Town, Wenzhou, Zhejiang, China

    JOIN US

    Register as one of our members and provide you with the latest product and discount information.