 VS1

 

VS1 series current mode voltage sensor is a device based on the principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC AC or pulsed currents.

Electrical data (Ta=25℃±5)

 

 

Type

VS1-5mA

VS1-10mA

Unit

Rated current(Ipn)

5

10

mA

Measure range(Ip)

7

14

mA

Turns ratio(Np/Ns)

5000:1000

2500:1000

T

Primary coil resister

650

200

Ω

Secondary coil resister

110

110

Ω

Measure resister

100~350

100~190

Ω

Rated output

25

25

mA

Supply voltage

±12,±15

V

Power Consumption

≤20+ IpX(Np/Ns)

mA

Offset current

@Ip=0                   ±0.2

mA

Offset drift

@ -40~+85℃            ≤±0.5

mA

Linearity

@Ip=0-±Ipn             ≤0.2

%FS

Response time

≤40

μS

Galvanic isolation

@ 50HZ,AC,1min           2.5

KV

Applications 

·AC variable speed drives

·Static converters for DC motor drives

·Battery supplied applications

·Uninterruptible Power Supplies (UPS)

·Switched Mode Power Supplies (SMPS)

·Power supplies for welding applications
Mechanical dimension(for reference only)

 

Remarks

1. All dimensions are in mm.

2. General tolerance ±1mm.
Directions for use
 

1. The accuracy of sensor will be the best when the current passes through resister R1 and becomes the rated primary current, and therefore the current to be measured by sensor should comply with the primary current 10mA.

2.Samples VIN=250V For example, VIN=250V:

Accuracy =±0.8%ofVIN(@Ta=+25      a) R1=25KΩ /10W,IP =10mA

Accuracy =±1.6%ofVIN(@Ta=+25      b) R1=50KΩ / 5W,IP =5mA

3. Considering resistance of primary coil (compared with R1 and temperature difference kept as low as possible) and electrical isolation within measure range (recommended), this sensor is suitable for measuring voltage.
Standards 

·UL94-V0.

·EN60947-1:2004

·IEC60950-1:2001

·EN50178:1998

·SJ 20790-2000
General date

 

Value

Unit

Operating temperature (TA)

-40 to +85

Storage temperature(TS)

-40 to +125

Mass(approx) (M)

22

g

Inquiry Form