 JLSZYo-35W voltage transformer

Description and meaning of model

This type of voltage,current combined transformer (also known as energy metering box)for the exchange of 50Hz,rated voltage of 10kV three-phase power lines for active and reactive energy metering.Apply to rural outdoor substation.Also be used for the small change of the industrial enterpries,power distribution.This product can replace the JLS-10 oil-immersed power metering box.

Characteristic of structure

The combined transformer for outdoor epoxy casting,all closed,the pillar structure.Outdoor epoxy casting,the product has the arc resistance.aging resistance,long life  ,maintenance-free characteristics .This product consists of two single-phase full insulation voltage transformer formed a "V"-shaped connection,two current transformer are connected in series A and C phase.And current transformer secondary winding with a tap can be obtained with different current ratio.

Technical Data

1.Pollution class: class II

2.This combination transformer by the combination of single -phase voltage transformer bearing in mind that single-phase current transformer into a three-phase .Voltage transformer with V/V-12 connection

3.This type of combination of transformer to meet with GB1208 current transformer ,GB1207 electromagnetic voltage transformer,GB17201 combined transformer ,requirements

4.Rated voltage of the voltage transformer ratio:10000/100(V).Rated secondary output:20VA 0.5 0.2 50VA

5.Load power factor COS towel=0.8(lag)

6..Current transformer meter safety factor Fs<10

7.Ambient temperature:-30 - 40℃。The daily average temperature does not exceed 30

8.Altitude<4000m

9.Other technical parameters are as follows

Rated primary current Rated short time thermal current (kA)(rms) Rated Dynamic current(kA)(peak) Rated secondary output Reted insulating level
0.2S 0.5
5-10 1 2.5 10 15 40.5/80/185
10-20 1.5 3.75
15-30 2.4 6
20-40 3 7.5
30-60 4.5 11
40-75 8 20
50-100 9 22.5
75-150 12 30
100-200 16 40
150-300 24 60
200-400 32 80
300-600 60 100
400-800 80 100
500-1000 80 100
Outline dimension