Products Type
Contact Us

HEYI Electrical CO.,LTD

Contact person: Bethy

Position: Sales Manager

Tel: 86-577-62659558

Fax: 86-577-61712987

Mobile: 86-13968747975

E-mail: heyi@heyiele.com

bethy@heyiele.com

Skype: bethycai

ADD: #21 ShangYou North 

Road, HuangHua LiuShi YueQing,

Zhe Jiang, CHINA

http://www.heyiele.com

Product

Home » Product
 D6

 

The D6 Series current sensor is a closed loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit, the size of primary doesn’t affect test precision, no matter the location of primary in the hole of current sensor. It can really measure resolution 1000:1, it uses for precision measurement of DC, AC and pulse current.

Electrical data (Ta=25℃±5)  

Type

D6-300A

D6-500A

Unit

Rated current(Ipn)

±300

±500

A

Measure range(Ip)

0—±500

0—±800

A

Turns ratio(Np/Ns)

1:3000

1:5000

T

Measure resister with±15V

@±300Amax
0(min)95(max)

@±500Amax
0(min)62(max)

Ω

@±500Amax
0(min)40(max)

@±800Amax
0(min)11(max)

Ω

Measure resister with±18V

@±300Amax
0(min)122(max)

@±500Amax
0(min)88(max)

Ω

@±500Amax
0(min)58(max)

@±800Amax
0(min)30(max)

Ω

Coil resister

31

50

Ω

Rated output

100

100

mA

Supply voltage

±12,±15,±18

V

Power Consumption

≤20+IpX(Np/Ns)

mA

Offset current

@Ip=0                     ±0.2

mA

Offset drift

@ -40~+85℃               ≤±0.5

mA

Linearity

@Ip=0-±Ipn                 ≤0.1

%FS

Response time

@50A/μS, 10%-90%         ≤1

μS

Galvanic isolation

@ 50HZ,AC,1min              6

KV

di/dt

>100

A/us

Bandwidth

@ -1dB                    0~150

KHZ

Applications

 ·Variable speed drives

·Welding machine

·Battery supplied applications

·Uninterruptible Power Supplies (UPS)

·Electrochemical

Mechanical dimension(for reference only)

 

Remarks

1. All dimensions are in mm.

2. General tolerance ±1mm.

3. Elucidation:  1:+15V  2:–15V  3:I0UT  4:NC

Directions for use

1. When the current will be measured goes through a sensor, the current will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)

2. Custom design in the different rated input current and the output current are available.

Standards

·UL94-V0.

·EN60947-1:2004

·IEC60950-1:2001

·EN50178:1998

·SJ 20790-2000
General date

 

Value

Unit

Operating temperature(TA)

-40 to +85

Storage temperature(TS)

-40 to +125

Mass(approx) (M)

290

g

Characteristics chart

 

Inquiry Form
Products Images:
Produt: D6
Full Name: *
Address:
Phone:
Email Address: *
Message: *
Upload Photos:
Contact Online bethycai 285611779 86-13968747975 bethy@heyiele.com