 CP Series Current transformer


CP range of current transformers are compact-smaller than other models with the current ratio of the transformer

is small.Clamshell-style terminal cover is well protected by the second terminal.

With related accessories you can use Din rail mounting a current from 5A to 3000A.
Features:

Three built in fixing methods: Panel/Din Rail/Busbar
Built in hinged terminal cover
Compact design

Primary current from 5A to 3000A

Applications:
Current measurement, monitoring and protection for electrical wiring and equipment.
Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system,

air-condition equipment and automation-control system.
Current, power and energy monitoring device.
Relay protection device.
Technical Index:

Electrical Parameter
Mechanical Parameter
Frequency 50/60Hz Case PC/UL94-V0
Rated Input 5A-3000A Bobbin PBT
Measuring range 5%In-120%In Core Silicon steel
Rated Output 1A,5A Construction Screw
Ratio Voltage 0.72KV (AC) Operating Temp -25℃~+75℃
Dielectric strength 3.0KV/1mA/1min Operating Humidity ≤85%
Insulation Resistance DC500V/100MΩ min Output Connection Terminal


Technical Parameter


Model Primary / Secondary Busbar Hole Dimensions(mm) Rated Burden (VA) Accuracy Class Rated Voltage
CP-62/B 5/5A~150/5A busbar 1.5~2.5 0.5 /1.0 0.72KV(AC)
CP-45/14 5/5A~60/5A Φ=14mm
1~2.5 0.5/1.0 0.72KV(AC)
CP-62/20 30/5A~200/5A Φ=20mm
1.5~5 0.5 /1.0
0.72KV(AC)
CP-62/30 30/5A~200/5A Φ=30mm
1.5~5 0.5 /1.0
0.72KV(AC)
CP-62/40 60/5A~300/5A Φ=40mm
2.5~5 0.5 /1.0
0.72KV(AC)
CP-74/50 300/5A~600/5A Φ=50mm
2.5~5 0.5/1.0 0.72KV(AC)
CP-80/30 30/5A~200/5A Φ=30mm
2.5~5 0.5 /1.0
0.72KV(AC)
CP-80/40 100/5A~500/5A
Φ=40mm
2.5~10 0.5/1.0 0.72KV(AC)
CP-86/60 250/5A~1000/5A Φ=60mm
3.75~15 0.5/1.0 0.72KV(AC)
CP-100/60 400/5A~1600/5A Φ=60mm
3.75~20 0.5/1.0 0.72KV(AC)
CP-104/80
600/5A~2000/5A Φ=80mm
10~20 0.5/1.0 0.72KV(AC)
CP-140/100 800/5A~3000/5A Φ=100mm
15~25 0.5/1.0 0.72KV(AC)

Dimension of case (mm):

Special remind:

1:The installation altitude less than 2000m

2:The surrounding temperature range: from -5°C ~ +40°C

3:In the non-explosive condition. or without adequate erosion and destruction of gas and dust conductive area .

4:Without  rain and snow invade

5:Pollution level 2