B203XT Series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit, the size of primary doesn’t affect test precision, no matter the location of primary in the hole of current sensor. It can really measure resolution 1000:1 and uses for precision measurement of DC, AC and pulse current.

Electrical data (Ta=25℃±5)

Type

B203XT-
10A

B203XT-
25A

B203XT-
50A

B203XT-
75A

B203XT-
100A

Unit

Rated current(Ipn)

±10

±25

±50

±75

±100

A

Measure range(Ip)

0—±15

0—±37

0—±75

0—±90

0—±120

A

Turns ratio(Np/Ns)

1:1200

1:1200

1:1200

1:1500

1:2000

T

Inside measuring resistance

30±0.1%

12±0.1%

6±0.1%

5±0.1%

5±0.1%

Ω

Rated output

@Ip=±Ipn               ±1±0.2%

V

Supply voltage

+5V

V

Power Consumption

20+ IpX(Np/Ns)

mA

Reference voltage

+2.5±0.4%

V

Zero voltage

@Ip=0                   +2.5±0.4%

V

Offset drift

@ -40~+85℃              ≤±0.05

mV /℃

Output drift

@ -40~+85℃              ≤±0.05

mV /℃

Linearity

@Ip=0-±Ipn                ≤0.1

%FS

Response time

@100A/μ S,10%-90%       ≤0.5

μs

Galvanic isolation

@ 50HZ,AC,1min             3

KV

Bandwidth

@ -3db                    0~200

KHZ

Applications

 ·Variable speed drives

·Welding machine

·Battery supplied applications

·Uninterruptible Power Supplies (UPS)

· Electrochemical

Mechanical dimension(for reference only)

 

Remarks

1. All dimensions are in mm.

2. General tolerance ±1mm.

Directions for use

 

1. Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.

2. The primary conductor should be120.

3. The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.

4. The primary turns should be at the top of the sensor for the best magnetic coupling.

5. When the current will be measured goes through a sensor, the voltage will be measured at the output end. (Note: The false wiring may result in the damage of the sensor)

6. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.

·EN60947-1:2004

·IEC60950-1:2001

·EN50178:1998

·SJ 20790-2000

General date

 

Value

Unit

Operating temperature(TA)

-40 to +85

Storage temperature (TS)

-40 to +125

 Mass(approx) (M)

15

g